ASTM E1105 vs. AAMA 502 Window Water Testing

The windows leak, and everyone has a reason it is someone else’s problem. The manufacturer says the product is fine. The installer points to the general contractor, and the general contractor points back. You may even have an ASTM E1105 test report that says the windows passed, while water still shows up on the sills after every storm.

ASTM E1105 and AAMA 502 are the field tests most often used to settle the question under that argument: is the leak coming through the window, or around it? The answer decides who is responsible and which recovery path applies. AMPR Consulting coordinates independent testing and the experts who run it for owners of multifamily and commercial buildings. AMPR then connects the results to responsibility through its construction defect claims consulting.

Send us the test report you were given. A passing result can still answer the wrong question.

What Is ASTM E1105?

ASTM E1105 is the Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference. The current version is ASTM E1105-15(2023). A spray rack wets the outside face of the installed unit. At the same time, a sealed chamber on the inside creates an air pressure difference, which pushes water inward the way wind-driven rain does.

Procedure A and Procedure B

  • Procedure A (uniform pressure): water sprays at 5 gallons per square foot per hour while pressure stays constant, usually for 15 minutes.
  • Procedure B (cyclic pressure): the same spray, but the pressure turns on and off. A common setup is four cycles of 5 minutes at pressure and 1 minute released.

Cyclic pressure is closer to gusting wind. It can find leaks that steady pressure misses.

What ASTM E1105 Can and Cannot Show

The standard is written mainly to check the manufactured assembly. Its scope also says that it can test the joints between the assembly and the adjacent construction. That sentence matters for owners. A test program that uses it can tell you if the window leaks or if the opening around it leaks. A test program that does not use it can tell you only about the window.

What Is AAMA 502?

AAMA 502 is the Voluntary Specification for Field Testing of Newly Installed Fenestration Products. Fenestration is the industry term for windows, doors and skylights. The current edition, AAMA 502-21, is published by the Fenestration and Glazing Industry Alliance (FGIA). It uses ASTM E1105 for the water test itself.

AAMA 502 Test Pressure, in Real Numbers

AAMA 502 water tests run at two-thirds of the product’s rated water test pressure. This recognizes that a field unit is not a lab specimen. The math shows how much that reduction matters:

  • A window with a design pressure (DP) rating of 50 has a lab water test pressure of 7.5 pounds per square foot (psf), which is 15 percent of DP.
  • At two-thirds, the AAMA 502 field test runs at 5.0 psf.
  • As a rough rule, 5.0 psf is about the pressure of a 44 mph wind. 7.5 psf is about 54 mph.

A window can pass AAMA 502 and still leak in a storm with stronger gusts. That is not a flaw in the test. It is a limit to know before anyone reads a passing result as proof.

The Six-Month Window

AAMA 502 is for new installations, usually tested within six months of installation. Most owners find leaks after that, in the first few rainy seasons. At that point, AAMA 502 no longer fits, and a builder’s “it passed AAMA 502 at turnover” tells you little about the building today.

What AAMA 502 Does Not Cover

AAMA 502 excludes curtain wall, storefront and sloped glazing. Those systems go under AAMA 503, the companion specification for newly installed storefronts, curtain walls and sloped glazing.

What Is AAMA 511?

AAMA 511 is the Voluntary Guideline for Forensic Water Penetration Testing of Fenestration Products. AAMA 502 asks if a new unit meets a specification. AAMA 511 asks a different question: where is the water that is already getting in coming from? It is the usual reference on older buildings. It builds on ASTM E2128, the guide for evaluating water leakage of building walls, which starts with document review and leak history before any water goes on the wall.

AAMA 511 is a guideline, not a pass/fail specification. Its purpose is to recreate a known leak and trace the path. For an owner with an active claim, that is often the more useful question.

What Is AAMA 501.2?

AAMA 501.2 is a field check that uses a calibrated hose nozzle to spray water at joints and seams. It is designed for storefronts, curtain walls and sloped glazing, as a quality assurance and diagnostic tool. It does not use a pressure chamber.

The Wrong-Test Problem

AAMA 501.2 needs less equipment than AAMA 502, so it is sometimes used in its place. On operable windows, the concentrated nozzle spray almost guarantees leaks at seals and weeps that were never designed for it. A failed 501.2 test on an operable window can be as misleading as a passed 502 test at low pressure. In both cases, check the standard before you look at the result.

How the Four Window Water Tests Compare

Standard When it is used What it proves Limits
ASTM E1105 Field testing of installed windows, doors, skylights, curtain walls Whether water penetrates under defined pressure; can include perimeter joints Results depend on chosen pressure, duration, and what is isolated
AAMA 502 Newly installed windows and doors, typically within six months Whether new installations perform in the field Reduced test pressure; excludes curtain wall and storefront
AAMA 511 Existing fenestration with known leaks Recreates and traces known leak paths Forensic guideline, not a pass/fail spec
AAMA 501.2 Storefronts, curtain walls, sloped glazing Locates leaks at joints and seams Hose test only; no pressure difference; wrong tool for operable windows

Window or Installation: How Testing Isolates the Leak

The value of window water testing is in isolating the leak path. A well-designed test separates two sources.

Product Leaks

Water comes through the frame, glazing, seals or corner joints of the window itself. A product leak points to the manufacturer, often under warranty.

Installation Leaks

Water comes around the window. Common paths are the flashing, the sill pan (the formed tray under the window that sends water back outside) and the tie-in to the weather-resistive barrier (the wrap behind the cladding). An installation leak points to the installer and the general contractor. That is a construction defect claim, and it often involves their liability insurance or the project’s wrap-up policy.

The Testing Sequence

  • Mask the perimeter so only the unit takes water and pressure.
  • Test the unit.
  • Remove the masking and test the perimeter joint.
  • Record where and when water first appears, with photos and time stamps.
  • Repeat on enough units to show if the result is a single failure or a pattern.

One test program can separate the two sources. A program that skips step 3 cannot.

In California, this matters under the Right to Repair Act (SB 800). Its functional standard for windows in homes and condominiums covers water that passes “around” the window, not only water that passes through it. HOA boards and owners can read more about how this applies to construction defect claims in California.

A Test Can Be Run Correctly and Still Answer the Wrong Question

A product-only test can pass while the installation leaks, because nobody tested the perimeter. A test at reduced pressure can pass on a unit that leaks in real storms. A test on the units that leak least can pass on a building where most units fail.

The person who chooses the test pressure, the duration and the locations shapes the result. That is why the choice of standard and the test plan need as much attention as the outcome.

How to Read a Window Water Test Report

When you receive a test report, check these eight items:

  • Which standard and procedure were used (for example, ASTM E1105 Procedure A or B).
  • The test pressure and how it was derived from the product rating.
  • Duration and cycles of each test.
  • Which units were tested and how they were selected.
  • What was masked or isolated, and whether the perimeter was tested.
  • Where and when water appeared, with photos.
  • The pass/fail criteria applied.
  • Who ran and who witnessed the test.

If items 2, 4 or 5 are missing, the report cannot tell you who is responsible, however clean the result looks.

Why Builder or Manufacturer Tests Need Independent Review

Tests commissioned by a manufacturer, installer or builder are not necessarily wrong. But the party that ran the test chose the standard, the pressure and the locations, and each of those choices can favor a result. An independent review checks if the test answered the question that matters to the owner: where the water is coming from across the building.

HOLDING A “PASSED” REPORT?

A passing result only answers the question the test was designed to ask. Have the report checked against the leaks you are actually seeing before you accept it.

Get the Window Test Report Reviewed

Test Before Repairs to Keep the Evidence

When windows are removed or re-flashed, the conditions that caused the leak are gone. Window leak testing should happen before repairs, with openings documented and representative samples preserved. If repairs come first, the owner can be left unable to show what failed or who was responsible. This is the same logic behind what is a construction defect and how it is proved: the record has to exist before the fix.

How Carriers Value Window Leak Claims

Carriers often value window claims low and treat them as isolated seal or caulk issues. A valuation under $1,500 for what is presented as a single-window problem is a common carrier position. When testing shows a pattern across many units, such as the same flashing error at every sill, the carrier has a different set of facts to evaluate. AMPR builds that technical record and coordinates the experts behind it. The carrier makes its own decision on the new facts. Our forensic investigations post covers how those patterns are built into the record.

Frequently Asked Questions

What is the difference between ASTM E1105 and AAMA 502?

ASTM E1105 is the field test method for water penetration under air pressure. AAMA 502 is a specification for field testing newly installed windows and doors that uses ASTM E1105 for the water test. It runs at about two-thirds of the rated test pressure, typically within about six months of installation.

What pressure does AAMA 502 use for water testing?

Two-thirds of the product’s rated water test pressure. For a window rated at DP 50, that is about 5.0 psf in the field, compared to 7.5 psf in the lab.

Can ASTM E1105 show whether the window or the installation is leaking?

Yes, when the test is designed to isolate the unit from the perimeter. Testing in sequence and recording where water first appears separates product leaks from installation leaks. Our window installation defects page covers what happens when the perimeter is the problem.

Can AAMA 501.2 be used instead of AAMA 502?

Not on operable windows. AAMA 501.2 is a hose check for storefronts, curtain walls and sloped glazing. On operable windows it tends to produce leaks that do not reflect real performance, so the result is unreliable in either direction.

What test should be used on an older building?

AAMA 502 is built for new installations. On older buildings, forensic testing often follows AAMA 511, which focuses on recreating known leaks, together with ASTM E1105 procedures as appropriate.

Why did my windows pass the test but still leak?

The test may have checked only the product and not the perimeter, used a pressure lower than real storm conditions, or tested units that were not leaking. A test can be run correctly and still answer the wrong question. If a carrier used that result to deny or undervalue the claim, see how AMPR approaches a denied property insurance claim.

Who is responsible for leaking windows on a new building?

If testing shows a product failure, the manufacturer may be responsible under warranty. If it shows an installation failure, the installer and general contractor may be responsible. Owners and developers and HOA construction defect support pages cover how each group builds that claim.

Should window testing be part of due diligence?

For buildings with a history of leaks, yes. Testing before acquisition can reveal installation patterns that affect value. See our guide to due diligence before closing and our commercial property risk assessments.

Who should coordinate window water testing?

Owners get the most from one team that sets the test plan, coordinates the testing agency and experts, and connects the results to responsibility. AMPR does this for owners and developers and works alongside the owner’s counsel. See the AMPR construction defect claims process for how an engagement runs.

Make the Test Answer the Right Question

ASTM E1105, AAMA 502, AAMA 511 and AAMA 501.2 each answer a specific question. The right standard and the right test plan show if water enters through the window or around it, and that decides who is responsible. AMPR coordinates independent testing, experts and counsel from the start, with a resolution-first approach designed to avoid litigation when possible. Past matters are on our client results page.

Put the test report next to the leaks before anyone repairs. Contact AMPR or call (310) 361-0209. The first conversation is a no-cost initial conversation, and engagement terms are discussed openly.

Get the Window Test Report Reviewed

Share This Post

  • Share on Facebook
  • Share on X
  • Share on WhatsApp
  • Share on Pinterest
  • Share on LinkedIn
  • Share on Tumblr
  • Share on Vk
  • Share on Reddit
  • Share by Mail

More Like This

Stucco Inspection Before An Hoa Files A Defect Claim

Stucco Inspection Before an HOA Files a Defect Claim

Commercial Construction
https://www.amprconsulting.com/wp-content/uploads/2026/11/Stucco-Inspection-Before-an-HOA-Files-a-Defect-Claim.jpg 1250 2000 Abstrakt Marketing /wp-content/uploads/2025/11/AMPR-Logo-Color-300x100.png Abstrakt Marketing2026-11-23 07:12:292026-11-23 07:16:12Stucco Inspection Before an HOA Files a Defect Claim
The Sb 800 California Right To Repair Process For Hoa Boards

The SB 800 California Right to Repair Process for HOA Boards

Commercial Construction
https://www.amprconsulting.com/wp-content/uploads/2026/11/The-SB-800-California-Right-to-Repair-Process-for-HOA-Boards.png 1250 2000 Abstrakt Marketing /wp-content/uploads/2025/11/AMPR-Logo-Color-300x100.png Abstrakt Marketing2026-11-23 07:06:082026-11-23 07:11:29The SB 800 California Right to Repair Process for HOA Boards
Construction Expert Witness Selection For Owners

Construction Expert Witness Selection for Owners

Commercial Construction
https://www.amprconsulting.com/wp-content/uploads/2026/11/Construction-Expert-Witness-Selection-for-Owners.png 1250 2000 Abstrakt Marketing /wp-content/uploads/2025/11/AMPR-Logo-Color-300x100.png Abstrakt Marketing2026-11-23 06:59:092026-11-23 06:59:14Construction Expert Witness Selection for Owners
What To Do When Your Insurance Company's Inspection Doesn't Match What You're Seeing

What to Do When Your Insurance Company’s Inspection Doesn’t Match What You’re Seeing

Commercial Construction
https://www.amprconsulting.com/wp-content/uploads/2026/10/What-to-Do-When-Your-Insurance-Companys-Inspection-Doesnt-Match-What-Youre-Seeing.jpg 1250 2000 Abstrakt Marketing /wp-content/uploads/2025/11/AMPR-Logo-Color-300x100.png Abstrakt Marketing2026-10-08 11:12:322026-10-08 11:12:37What to Do When Your Insurance Company’s Inspection Doesn’t Match What You’re Seeing
What To Expect When Your Lender Requires A Property Condition Assessment

What To Expect When Your Lender Requires a Property Condition Assessment

Commercial Construction
https://www.amprconsulting.com/wp-content/uploads/2026/10/What-To-Expect-When-Your-Lender-Requires-a-Property-Condition-Assessment.jpg 1250 2000 Abstrakt Marketing /wp-content/uploads/2025/11/AMPR-Logo-Color-300x100.png Abstrakt Marketing2026-10-08 11:06:412026-10-08 11:06:47What To Expect When Your Lender Requires a Property Condition Assessment
Latent Defect Insurance Claims: What Coverage Professionals Need to Verify

Latent Defect Insurance Claims: What Coverage Professionals Need to Verify

Commercial Construction
https://www.amprconsulting.com/wp-content/uploads/2026/10/What-to-Look-for-When-Choosing-a-Construction-Defect-Consultant-1.jpg 1250 2000 Abstrakt Marketing /wp-content/uploads/2025/11/AMPR-Logo-Color-300x100.png Abstrakt Marketing2026-10-08 08:51:132026-10-08 08:51:18Latent Defect Insurance Claims: What Coverage Professionals Need to Verify
What To Look For When Choosing A Construction Defect Consultant

What to Look for When Choosing a Construction Defect Consultant

Commercial Construction
https://www.amprconsulting.com/wp-content/uploads/2026/10/What-to-Look-for-When-Choosing-a-Construction-Defect-Consultant.jpg 1250 2000 Abstrakt Marketing /wp-content/uploads/2025/11/AMPR-Logo-Color-300x100.png Abstrakt Marketing2026-10-08 08:45:492026-10-08 08:45:54What to Look for When Choosing a Construction Defect Consultant
What Your Construction Contract Doesn't Tell You About Defect Liability

What Your Construction Contract Doesn’t Tell You About Defect Liability

Commercial Construction
https://www.amprconsulting.com/wp-content/uploads/2026/10/What-Your-Construction-Contract-Doesnt-Tell-You-About-Defect-Liability.jpg 1250 2000 Abstrakt Marketing /wp-content/uploads/2025/11/AMPR-Logo-Color-300x100.png Abstrakt Marketing2026-10-08 08:33:422026-10-08 08:34:17What Your Construction Contract Doesn’t Tell You About Defect Liability
The Exterior Facade Of A Generic Small Business

Property Risk Management for Commercial Real Estate: When a Formal Assessment Changes the Outcome

Commercial Construction
https://www.amprconsulting.com/wp-content/uploads/2026/08/The-exterior-facade-of-a-generic-small-business.jpg 1250 2000 Abstrakt Marketing /wp-content/uploads/2025/11/AMPR-Logo-Color-300x100.png Abstrakt Marketing2026-08-27 08:54:592026-08-27 08:55:09Property Risk Management for Commercial Real Estate: When a Formal Assessment Changes the Outcome
Previous Previous Previous Next Next Next

Categories

  • Commercial Construction
  • Construction Defect
  • Developers
Ampr Logo Color White

About Us

AMPR Consulting provides high-level guidance that strengthens defect claims and sharpens risk planning for stronger property protection.

What We Do

Construction Defect Claims Consulting

Exposure & Vulnerability Assessments 

 

Contact Us

8820 Wilshire Blvd #200
Beverly Hills, CA 90211

(310) 361-0209

[email protected] 

Website by Abstrakt Marketing Group ©
  • Privacy Policy
  • Sitemap
Scroll to top Scroll to top Scroll to top

This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.

AcceptLearn more

Cookie and Privacy Settings



How we use cookies

We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.

Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.

Essential Website Cookies

These cookies are strictly necessary to provide you with services available through our website and to use some of its features.

Because these cookies are strictly necessary to deliver the website, refusing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.

We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.

We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.

Other external services

We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.

Google Webfont Settings:

Google Map Settings:

Google reCaptcha Settings:

Vimeo and Youtube video embeds:

Accept settingsHide notification only